Resistance temperature detector according to or similar to DIN 43772
RTD with protective fitting Form 4F
- Note: also available as type-tested Ex i version according to ATEX and IECEx for measuring in zone 0 (D-sleeve),
Type in Ex operating instructions WR15-L, type of ignition protection Ex ia IIC T1...T6 Gb or Ex ia IIIC T135 °C Db. - Process connection: via welding sleeve (D-sleeve) with welded on blind flange according to or similar to DIN EN 1092-1 type 05 or ASME B 16.5.
- Area of application: Autoclaves, machine and plant construction, chemical, food and beverage industry, energy and power plant technology, sanitary, heating and air-conditioning technology.
- Measuring range depending on sensor type -50 to 600°C, sensor according to DIN EN 60751.
- Standard material of protective fitting 1.4571, preferred holder tube Ø 11x2x140 mm, preferred thread M14, M18 or G1/2".
- Measuring insert exchangeable in accordance with DIN 43735.
- Also with optional directly mounted transmitter.
Downloads
information material- Data sheet Ex_RTD model 4F_136090_GB
- Data sheet RTD model 4F_139591_GB
- Datenblatt Ex_WTH Form 4F_136090_DE
- Datenblatt WTH Form 4F_139351_DE
- Ex-Betriebsanleitung R15 DE
- Ex-operating instructions R15 GB
- Ex-operating instructions R15 RU
- Installationsanweisung WTH DE
- operating manual WTH ES
- operating manual WTH FR
- operating manual WTH GB
- operating manual WTH IT
- operating manual WTH RU
- ATEX Quality Assurance Notifivation FR
- ATEX Quality Assurance Notifivation GB
- ATEX Qualitätssicherungssystem DE
- BVS 17 ATEX E 110 X 1. Nachtrag_DE
- BVS 17 ATEX E 110 X Supplement 1 GB
- IECEx BVS 17.0091X Supplement 1 GB
- Datenblatt MTE Ausf BM mit freien Enden_137325_DE
- SIL Declaration of Conformity DE
- SIL Declaration of Conformity GB
- SIL Declaration of Conformity IT