Mineral insolated thermocouple assembly according to or similar to DIN 43772
MIT with flange protection shell model 3F (with "Namur" tapered measuring tip, faster response time)

  • Note: also available as type-tested Ex i version in accordance with
    ATEX and IECEx for measuring in zone 0, 

    Type in Ex operating instructions manual TR15-J, Ex ia IIC T1...T6 Ga/Gb
    or Ex ia IIIC T135 °C Da/Db.
  • Process connection: Blind flange according to or similar to DIN EN 1092-1 type 05 or ASME B 16.5.
  • Area of application: Autoclaves, machine and plant construction, chemical, food and beverage industry, energy and power plant technology, sanitary, heating and air-conditioning technology.
  • Measuring range depending on thermocouple -50 to 1100°C, also from -196 °C on request.
  • Standard material of protective fitting 1.4571, preferred diameter 12 to 9 mm or 14 to 11 mm .
  • Measuring insert exchangeable in accordance with DIN 43735.
  • Thermocouples according to DIN EN 60584-1, insulated or welded to the floor.
  • Optionally also with directly mounted transmitter.

Online request / Configurator

MIT model 3F flange Namur tapered protection shell and neck tube IP54 on request up to IP67

Your choice

Your note