Small thermocouple model BK according to DIN EN 50446
straight thermocouple with ceramic protection tube, metallic neck tube, connection head in Form B and MIT measuring insert (model BM)

  • Under certain conditions, use in hazardous areas is possible on request.
  • Process connection with separate stop flange, gas-tight threaded socket or welded-on flange.
  • Area of application: Steel/iron, aluminium/non-ferrous metal industry, industrial furnace construction, automotive industry, heat treatment, plant/mechanical engineering, energy, research and development, waste incineration/recycling, cement/construction materials.
  • Measuring range depending on sheath material and thermocouple up to 1100°C.
  • Ceramic protection tube made of C 610 or C 799, preferred diameter 15 mm.
  • Measuring insert exchangeable according to or similar to DIN 43735.
  • Thermocouples according to DIN EN 60584-1, insulated or welded to the floor.
  • On request with calibration (also according to AMS 2750 or CQI 9) in our accredited laboratory according to DIN EN 17025 (measured variable temperature)

Online request / Configurator

small thermocouple with ceramic protection tube, neck tube and MIT measuring insert

Your choice

Your note