Mineral insolated thermocouple assembly according or similar to DIN 43772
MIT with neck tube and thermowell model 4

  • Note: also available as type-tested Ex i version in accordance with
    ATEX and IECEx for measuring in zone 0, 

    Type in Ex operating instructions manual TR15-K, Ex ia IIC T1...T6 Gb
    or Ex ia IIIC T135 °C Db.
  • Process connection: via welding sleeve (D-sleeve), preferred lengths (L / U) 140/65 mm, 200/65 mm, 200/125 mm and 260/125 mm.
  • Area of application: Autoclaves, machine and plant construction, chemical, food and beverage industry, energy and power plant technology, sanitary, heating and air-conditioning technology.
  • Measuring range depending on thermocouple -50 to 1100°C, also from -196 °C on request.
  • Standard material of protective fitting 1.4571, preferred neck tube Ø 11x2x140 mm, preferred thread M14, M18 or G1/2".
  • Measuring insert exchangeable in accordance with DIN 43735
  • Thermocouples according to  IEC / EN 60584-1, insulated or welded to the floor.
  • Also with optional directly mounted transmitter.

Online request / Configurator

MIT model 4 with neck tube and thermowell

Your choice

Your note