Skip to main navigation Skip to main content Skip to page footer

Resistance thermometers according to or similar to DIN 43772
RT with protective fitting Form 3GoH (with tapered measuring tip, faster rresponce time)

  • Note: also available as type-tested Ex i version according to ATEX and IECEx for measuring in zone 0,
    Type
    in Ex operating instructions WR15-G, type of ignition protection Ex ia IIC T1...T6 Ga/Gb or Ex ia IIIC T135 °C Da/Db.
  • Process connection: Double nipple with all common threads, preferred thread G1/2".
  • Area of application: Autoclaves, machine and plant construction, chemical, food and beverage industry, energy and power plant technology, sanitary, heating and air-conditioning technology.
  • Measuring range depending on sensor type -50 to 600°C, sensor according to DIN EN 60751.
  • Note: Use only at non-critical process temperature due to "low" temperature decoupling via the double nipple.
  • Standard material of protective fitting 1.4571, preferred diameter 12 to 9 mm or 14 to 11 mm.
  • Measuring insert exchangeable in accordance with DIN 43735.
  • Also with optional directly mounted transmitter.

Ansprechpartner finden

Bitte geben Sie Ihre Postleitzahl ein, um die Kontaktdaten zu Ihrem Ansprechpartner zu erhalten.


RECKMANN GMBH




+49 (0) 2331 3501-0