9. Compensation and Extension Cables:


In accordance with DIN 43 722, compensation cables are marked with the letter "C", which is placed after the code letter of the corresponding thermocouple (e.g. "KC"). The electrical conductors (i.e. the flexible strands or solid wires) consist of so-called substitute materials that have a different chemical composition from the materials of the corresponding thermocouple (see the table at the end of this section). Various substitute materials may be used for a thermocouple type, with an additional letter "A" or "B" (e.g. "KCA" and KCB") being added to the designation of the cable in this case. The substitute materials have the same thermoelectric properties as the corresponding thermocouple in the application temperature range permissible for compensation cables. For the temperature range permissible according to cable type, see DIN 43 722. 
Compensation cables are used for thermocouple types K, N, R, S and B, as the substitute materials (particularly in the case of noble metal thermocouple types R, S and B) are much better priced than the (original) materials of the corresponding material. Extension cables for thermocouples (T/C extension cables) are designated, in accordance with DIN 43 722, with the letter "X", which is placed after the code letter of the corresponding thermocouple (e.g. "KX"). The electrical conductors consist of materials that nominally have the same chemical composition as the (original) materials of the corresponding thermocouple. The thermoelectric voltage of the conductor pairs, however, only needs to match the standardized basic values of the corresponding thermocouple to a temperature of 200°C (only up to 100°C for type TX).
T/C extension cables are available for thermocouple types K, N, J, T and E (all types in accordance with DIN IEC 584) as well as for types L and U (in accordance with DIN 43710). The limit deviations (tolerances) of the compensation and T/C extension cables are defined in DIN 43 722 (or in DIN 43 710 for cable types LX and UX) and apply to the cable’s condition at the time it is supplied. The limit deviation is the maximum additional deviation in microvolts that is produced in a measuring circuit if a compensation or T/C extension cable is inserted into it and the cable is inserted within its permissible temperature range.  
The loop resistance of compensation and T/C extension cables is of secondary importance in many cases, as modern electronic measuring devices have high input resistance, which means that even cable resistance of several kiloohms fails to cause significant measurement error.    
   
The following table provides an overview of the materials and colour codes of compensation and T/C extension cables and the materials of the corresponding thermocouples

   

 

Tabelle 1: Werkstoffe und Kennfarben (Übersicht) / Materials and colour codes
Thermopaare
thermocouples
Ausgleichs- und Thermoleitungen
compensation and extension cables
Kennfarben der Isolierung 2)
colour codes 2)
Norm
standard
Typ
type
Werkstoffe / materials
+ Pol        - Pol
Typ 1)
type 1)
Werkstoffe / materials
+ Pol        - Pol
+ Pol - Pol Mantel 3)
sheath 3)
Norm
standard
DIN EN 60584 J Fe CuNi JX Fe CuNi schwarz
black
weiß
white
schwarz
black
DIN EN 43722
T Cu CuNi TX Cu CuNi braun
brown
weiß
white
braun
brown
E NiCr CuNi EX NiCr CuNi violett
violet
weiß
white
violett
violet
K NiCr Ni KX NiCr Ni grün
green
weiß
white
grün
green
KCA Fe CuNi
KCB Cu CuNi
N NiCrSi NiSi NX NiCrSi NiSi rosa
pink
weiß
white
rosa
pink
NC Cu CuNi
R Pt 13% Rh Pt RCA Cu CuNi orange
orange
weiß
white
orange
orange
RCB Cu CuNi
S Pt 10% Rh Pt SCA Cu CuNi orange
orange
weiß
white
orange
orange
SCB Cu CuNi
B Pt 30% Rh Pt 6% Rh BC Cu Cu grau
grey
weiß
white
grau
grey
DIN EN 43710 U Cu CuNi UX Cu CuNi rot
red
braun
brown
braun
brown
DIN EN 43714
L Fe CuNi LX Fe CuNi rot
red
blau
blue
blau
blue


1) " ...C, ...CA, ...CB " : Ausgleichsleitungen / compensation cables
    " ... X : Thermoleitungen / extension cables for thermocouples
2) siehe Seite "Farbtabelle für internationale Kennfarben der Temperatur - Meßtechnik"
    see "international colour codes applied to temperature measuring engineering"
3) Außengeflechte (z.B aus Glasseide oder Stahldraht) besitzen einen entsprechend gefärbten Kennfaden im Geflecht.
     Uncoloured sheaths (e.g. armourings or fiber glass) have an appropriately coloures tracer.


   
   
Go to the Practice page        (Installing Temperature Sensors)

Content Management Software (c)opyright 2000-2011 by HELLMEDIA GmbH
Sensor
deutsch english franšais espa˝ol      print
Reckmann GmbH
Reckmann GmbH
 

 

 

Compensation and Extension Cables

Compensation and Extension Cables

Mitglied im
Member of
Membre du


AMA Logo mit Caim

 

News

 

Compensation and Extension Cables

Reckmann Reckmann
back to top  
back to top
Thermo
     Imprint © 2014 Reckmann GmbH | 
Design: EMANDU« Communications